6 8 Control system – 8.2 Monitoring 8.2 Monitoring page Monitoring functions, general The machine is equipped with a number of control functions to in- crease safety during load handling: Overloading system By-passing Load-centre limitation Height limitation Speed limitation Service indicator 8.2.1 Overloading system page Overloading system, general The machine is equipped with a warning system, LLMC (Longitudinal Load Moment Control). Warning systems shall ALWAYS be function- al! The system shall be used for stationary load handling, so that the machine's forward stability is not jeopardized. The following happens when the machine approaches the stability limit:
the buzzer in the cab sounds (indication to operator) warning figure is shown in the display (indication to operator) boom movement is interrupted In this position the boom, and thus the load, can only be retract- ed until the buzzer stops sounding and the display figure disap- pears. LLMC is not intended to control sideways stability or stability when operating. Also, it does not take angled ground conditions into ac- count. NOTE Retract the boom before it is lowered! Applies to all load han- dling! The overloading system is activated when the operator exceeds the machine's load handling capacity. When the overloading system is active all hydraulics are blocked, e.g., lift.
With Switch by-pass, cer- tain parts of the overloading system can be by-passed. This makes it possible to lower and retract the boom to avoid dangers. There are three versions of overloading system: Mechanical overloading system, function description page 8 Mechanical overloading system with analogue position sensors, function description page 9 Electrical overloading system, function description page 10 UDRF01.04GB Maintenance manual DRF 400–450