10 Common hydraulics – 10.4.2 Axial piston pump with variable displacement 9 page Hydraulic oil pump, checking WARNING Hot and pressurized oil. Personal injury, burn injury, rash or irritation. Always depressurize the hydraulic systems before starting to work in the hydraulic systems. Avoid skin contact with the oil, use protective gloves. 1 Operate and warm up the machine so that the hydraulic oil reaches operating temperature, approx. 50 ° C. 2 Turn off the engine. 3 Connect pressure gauge to pressure connection on hydraulic oil pump 1. 4 Start the engine and let it idle. 5 Check the stand-by pressure for one pump at a time in the fol- lowing order: Hydraulic oil pump 1:
1.8 MPa Hydraulic oil pump 2: 2.1 MPa Hydraulic oil pump 3: 2.9 MPa 1. Hydraulic oil pump 1 2. Hydraulic oil pump 2 3. Hydraulic oil pump 3 4. Hydraulic oil pump 4 Hydraulic oil pump 4: 3.1 MPa Settings apply to standard machine, certain machines may have higher stand-by pressure. For correct stand-by pressure, see pressure plate. However, the pressure difference between the pumps must always be maintained. 6 Increase engine speed to approx. 1100 r/min and run extension function against end-position (overflow). Run out the boom to max and continue to request max. exten- sion with the control lever. This will cause the overflow of the extension function.
UDRF01.04GB Maintenance manual DRF 400–450