11 Common electrics – 11.2.2 Fuses 5 11.2.2 Fuses page Fuses, description IMPORTANT Risk of cable damage and fire in cable harnesses! Always use fuses with the correct ampere rating. The electrical system has three main circuits (30, 15 and 15E volt- age), see Distribution of electricity, description page 10 . The main circuits are connected across fuses several times with main fuses and circuit fuses. Main fuses 1 2 The main fuses divide the machine's voltage feed into smaller parts to maintain as many functions as possible in case of damage to ca- bles harnesses. By the cab's and frame's electrical distribution boxes there are fuse plates that describe the different fuses.
F54 D793 F 58-3 F 58-2 F 58-1 K1 X168 3 K3 K2 K4 4 5 6 004925 Main fuses 1. Control breaker voltage (15E) to control units on boom and attachment, (25 A) 2. Frame ground connections for boom and attach- ment, (25 A) 3. Electric power feed relay K1, electric power to ig- nition voltage (15), (50 A) 4. Battery voltage (30) to cab, engine and transmis- sion, (50 A) 5. Electric power feed relay K2, electric power to control breaker voltage (15E), (50 A) 6. Ignition voltage (15) to control units on frame, en- gine and transmission, (50 A) UDRF01.04GB Maintenance manual DRF 400–450