Kaiyi UDRF01.04GB — Error codes engine alternative Volvo

D Error codes – 1 Engine 9 UDRF01.04GB Maintenance manual DRF 400–450 Descrip- tion Limitation Action Con- nec- tion and com- ponent Diag- nostic menu Function group Code Volvo code 105/4 26 DTC 3.3 Sensor charge-air tempera- ture, cable short- circuited to ground or open circuit. No limita- tion. Check cabling between control unit and compo- nent. Check that sensor charge- air temperature is installed correctly and connected. Check sensor charge-air temperature. D794/ Black:2 ENGINE, menu 7 1.6.6 Sensor charge-air temperature 110/0 31 DTC 6.1 High cool- ant tem- perature. Engine is shut off. Check coolant level. Check that radiator is clean. Check if there's air in cool- ant system.

Check the cap on the ex- pansion tank. Check sensor coolant tem- perature. Check thermostat. - ENGINE, menu 7 1.7 Cooling system 110/3 27 DTC 3.3 Sensor coolant tempera- ture, cable short- circuited to voltage or open circuit. Preheating activated even when engine is warm. Check that sensor coolant temperature is installed correctly and connected. Check cabling between control unit and compo- nent. Check sensor coolant tem- perature. D794/ Black:25 ENGINE, menu 7 1.7.9 Sensor coolant tem- perature 110/4 28 DTC 3.3 Sensor coolant tempera- ture, cable short- circuited to ground. Preheating activated even when engine is warm. Check cabling between control unit and compo- nent.

Check that sensor coolant temperature is connected correctly. Check sensor coolant tem- perature. D794/ Black:25 ENGINE, menu 7 1.7.9 Sensor coolant tem- perature 111/1 191 DTC 2.2 Low cool- ant level. Engine is shut off. Check the coolant level, top up if needed. Check sensor coolant level. - - 1.7 Cooling system