26 D Error codes – 1 Engine UDRF01.04GB Maintenance manual DRF 400–450 Descrip- tion Limitation Action Con- nec- tion and com- po- nent Diag- nostic menu Function group Code Cum- mins code 105/0 155 Warm inlet air Engine power is reduced suc- cessively, en- gine shuts off after 30 sec- onds. Check coolant level in the engine, top up if needed. Check that intercooler is clean, clean if needed. Check that fan belts are in- tact. Check sensor inlet temperature. - EN- GINE, menu 7 1.6 Air inlet and exhaust system 105/3 153 Sensor charge-air temperature, cable short- circuited to voltage or open circuit. Risk of white exhaust smoke. No warning for hear coolant temperature.
Check cabling between control unit and compo- nent. Check that sensor charge- air temperature is installed correctly and connected. Check sensor charge-air temperature. D794/ Sen- sor:38 EN- GINE, menu 7 1.6.6 Sensor charge-air temperature 105/4 154 Sensor charge-air temperature, cable short- circuited to ground or open circuit. Risk of white exhaust smoke. No warning for hear coolant temperature. Check cabling between control unit and compo- nent. Check that sensor charge- air temperature is installed correctly and connected. Check sensor charge-air temperature. D794/ Sen- sor:38 EN- GINE, menu 7 1.6.6 Sensor charge-air temperature 108/2 295 Electric mal- function air pressure, data error.
Reduced en- gine power. Check component. - - 1.6.5 Sensor boost pres- sure 108/3 221 Electric mal- function air pressure, ca- ble short- circuited to voltage. Reduced en- gine power. Check cabling between Control unit and compo- nent. Check component. D794/ Sen- sor:06 - 1.6.5 Sensor boost pres- sure 108/4 222 Electric mal- function air pressure, ca- ble short- circuited to ground. Reduced en- gine power. Check cabling between Control unit and compo- nent. Check component. D794/ Sen- sor:06 - 1.6.5 Sensor boost pres- sure