Kaiyi UDRF01.04GB — Error codes engine alternative Cummins

36 D Error codes – 1 Engine UDRF01.04GB Maintenance manual DRF 400–450 Descrip- tion Limitation Action Con- nec- tion and com- po- nent Diag- nostic menu Function group Code Cum- mins code 1043/ 4 443 Electric mal- function throt- tle pedal reference voltage, cable short- circuited to ground. Engine only runs at idle. Check cabling between Control unit and compo- nent. Check component. - - 1.1.2 Throt- tle pedal 1079/ 3 386 Electric mal- function refer- ence voltage to sensor short- circuited to voltage. Reduced en- gine power. Check cabling between Control unit and compo- nent. Check component.

D794/ Sen- sor:17, Sen- sor:37 - 1.9 Control system en- gine 1079/ 4 352 Electric mal- function refer- ence voltage to sensor short- circuited to ground. Reduced en- gine power. Check cabling between Control unit and compo- nent. Check component. D794/ Sen- sor:17, Sen- sor:37 - 1.9 Control system en- gine 1083/ 3 293 Electric mal- function extra sensor tem- perature, ca- ble short- circuited to voltage. No protection for tempera- ture (custom- er-specific option). Check cabling between Control unit and compo- nent. Check component. - - 1.9 Control system en- gine 1083/ 4 294 Electric mal- function extra sensor tem- perature, ca- ble short- circuited to ground.

No protection for tempera- ture (custom- er-specific option). Check cabling between Control unit and compo- nent. Check component. - - 1.9 Control system en- gine