Kaiyi UDRF01.04GB — Error codes transmission

D Error codes – 2 Transmission 53 UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 81.01 81.01 Electric mal- function gear selection 2/4, cable not con- nected or short- circuited to voltage. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve 2/4 (Y6074). Check solenoid valve gear selec- tion 2/4 (Y6074). D793/E2 - Y6074 TRANSM , menu 7 2.3.4 Valve block trans- mission con- trol 82.00 82.00 Electric mal- function gear selection 1/3, cable short- circuited to ground. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve gear selection 1/3 (Y6075).

Check solenoid valve 1/3-selection (Y6075). D793/F2 - Y6075 TRANSM , menu 7 2.3.4 Valve block trans- mission con- trol 82.01 82.01 Electric mal- function gear selection 1/3, cable not con- nected or short- circuited to voltage. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve gear selection 1/3 (Y6075). Check solenoid valve 1/3-selection (Y6075). D793/F2 - Y6075 TRANSM , menu 7 2.3.4 Valve block trans- mission con- trol 83.00 83.00 Electric mal- function drive, cable short- circuited to ground. Transmission in locked neutral po- sition (Shut-down mode). Check cabling to solenoid valve drive Check solenoid valve drive.

D793/K2 - Y6066 TRANSM , menu 7 2.3.4 Valve block trans- mission con- trol 83.01 83.01 Electric mal- function drive, cable not con- nected or short- circuited to voltage. Transmission in locked neutral po- sition (Shut-down mode). Check cabling to solenoid valve drive Check solenoid valve drive. D793/K2 - Y6066 TRANSM , menu 7 2.3.4 Valve block trans- mission con- trol 90.xx - 99.xx 90.xx - 99.xx System error. Transmission in locked neutral po- sition (Shut-down mode). Contact Kalmar In- dustries AB for more information. D793/ A:20 - 11.5.3.9 Con- trol unit trans- mission