Kaiyi UDRF01.04GB — Error codes machine

78 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 269 Transistor has been triggered due to short circuit or open circuit in circuit for solenoid valve side- shift right (Y6021). Sideshift of attachment not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:30 – Y6021 ATTACH, menu 6 7.4.3 Control valve attach- ment 270 Transistor has been triggered due to short circuit or open circuit in circuit for solenoid valve side- shift left (Y6020). Sideshift of attachment not working.

Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:31 – Y6020 ATTACH, menu 6 7.4.3 Control valve attach- ment 271 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for solenoid valve lock twistlock (Y6040). Twistlock not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:32 – Y6040 ATTACH, menu 7 7.9.1.3 Con- trol valve at- tachment 272 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for solenoid valve open twist- lock (Y6039). Twistlock not working.

Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:33 – Y6039 ATTACH, menu 7 7.9.1.3 Con- trol valve at- tachment 273 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for solenoid valve tilt 1 (Y6012- 1). Tilt lock not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:7 – Y6012-1 ATTACH, menu 13 7.7.4 Lock valve tilt 274 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for solenoid valve tilt 2 (Y6012- 2). Tilt lock not working. Check cabling between the control unit and component with diagnostic menu. Check component.

D791-1/ K1:9 – Y6012-2 ATTACH, menu 13 7.7.4 Lock valve tilt