D Error codes – 8 Control system 83 UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 351 Redundant voltage feed left to Control unit combi attach- ment left (D971-3) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D791-3/ K2:7 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 352 Redundant voltage feed right to Control unit combi attach- ment left (D971-3) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component.

D791-3/ K2:8 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 353 Control breaker voltage to Control unit combi attach- ment left (D791-3) below 18 V or above 32 V. Control breaker can- not be re- leased. All hydraulic functions blocked. Check fuse F58-3:1, change if needed. Check cabling between the control unit and component with diagnostic menu. D791-3/ K2:1/9/10 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 354 Incorrect control breaker voltage to Control unit combi attachment left (D791-3). Control breaker can- not be re- leased. All hydraulic functions blocked. Check fuse F58-3:1, change if needed.

Check cabling between the control unit and component with diagnostic menu. D791-3/ K2:11 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 361 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Work light left lift leg (H406). Work light left lift leg not working. Check light. Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D791-3/ K1:1 – H404-6L LIGHTS, menu 2 9.6.12 Work light attach- ment 362 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Solenoid valve levelling right (Y6035) or Solenoid valve levelling left (Y6036). Levelling not working.

Check cabling between the control unit and component with diagnostic menu. Check component. D791-3/ K1:15 – Y6035/ Y6036 ATTACH, menu 17 - 18 7.8.3 Control valve attach- ment