90 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 424 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Solenoid valve rear leg up (Y6061R). Right lift leg not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-4/ K1:9 – Y6061R COMBI, menu 13 7.9.2.3 Con- trol valve lift leg 425 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Indicator light (H580). Indicator light front legs raised not working. Check light.
Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D791-4/ K1:10 – H580 COMBI, menu 9 7.1.14 Light panel boom 426 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Indicator light (H581). Indicator light front legs lowered not working. Check light. Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D791-4/ K1:25 – H581 COMBI, menu 9 7.1.14 Light panel boom 427 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Indicator light (H578). Indicator light clamp- ing position lift leg front not working. Check light.
Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D791-4/ K1:29 – H578 COMBI, menu 8 7.1.14 Light panel boom 428 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Indicator light (H579). Indicator light clamp- ing position lift leg rear not working. Check light. Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D791-4/ K1:39 – H579 COMBI, menu 8 7.1.14 Light panel boom 451 Redundant voltage feed left to Control unit KID (D795) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component.
795/K1:7 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 452 Redundant voltage feed right to Control unit KID (D795) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. 795/K1:8 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 460 No messages are received on CAN buffer 1. Incorrect val- ues in oper- ating menus. Use diagnostic menu to check CAN bus – CAN/ POWER, menu 1 – 2 11.6.2 Redun- dant CAN bus