Kaiyi UDRF01.04GB — 1.7.2 Coolant filter

1 Engine – 1.7 Cooling system 15 1.7 Cooling system page Cooling system, description The engine radiator is located together with the Intercooler and transmission oil cooler in a unit, a cooling unit. For position of components, see Engine alternative Volvo, compo- nent position page 4 or Engine alternative Cummins, component po- sition page 7 . 1.7.2 Coolant filter page Coolant filter, changing (Volvo engine) NOTE Close the shut-off valve before the filter is loosened. Coolant may run out resulting in environmental damage. 1 Machine in service position, see section B Safety . 2 Close the shut-off valve on the filter holder. 3 Clean the area around the coolant filter.

4 Place a receptacle under the coolant filter. 5 Remove the coolant filter with filter tool. 6 Lubricate the O-ring on the filter cartridge with engine oil. 1. Shut-off valve 2. Coolant filter 7 Fit the new filter. Tighten to contact and then another half to three-quarter turn. 8 Open the shut-off valve on the filter holder. NOTE Do not forget to open the valve after changing. Otherwise, the coolant does not pass through the filter and is not cleaned. 9 Turn on the main electrical power and start the engine. 10 Check that the coolant filter seals tight. 11 Remove the receptacle. Handle the coolant as environmentally hazardous waste. UDRF01.04GB Maintenance manual DRF 400–450