PIPER COMANCHE SERVICE MANuAL e. If it was possible to elecmc::ally disconnect the saner from the starter solenoid. the starnng vibraror may be enc:rgi.zed by tumiftJ the stuter switch on. f. If starter wu not electrially removed from staner solenoid, it is necessary to connect a jumper lead from stancr swttch terminal on vibraror to ungrounded terminal on battery. This will energize the StartinJ vibrator. c. Holdinl the number one cylinder spark plug lead approximately 3/16 to 1/4 inch away from a load i!'ound. a series of hot sparks should occur. CAUTION Grasp the spark plat lead far enouJh away from the connection so as not to produce any dafttcrous elecmca.l shock. h.
If the spark does not jump the ,ap. check the applied voltale to the starting vibrator. This voluge should be either 1.2 or 24 volts ckpendinr upon the system being checked. i, If voltage is correct, check the contact points of the mllDeto. Both SCtS of contact p"inu shail be opened. J. Reject aU units not complyint with the preceding requirementS or which show any visual defects, 1B-48. Spark Plup. 18-49. Removal Of Spuk Plup. a. Loosen the coupling nut on the harness lad and remove the terminal insulator from the spark plug barrel well. NOTE When withdrawing the ignition cable lead connection from the plug.
care must be taken to pull the Ie:ld straight out and in line with the center line of the plug barrel; otherwise, a side load will be applied which frequently results in dam.,e to the burel. insulator and connector. If the lead C2.ftnot be removed easily in this manner, the resisting contact between the neoprene collar and the barrel insulator will be broken by a rotary twisang of the collar. Avoid undue distortion oi the collar and possible side loading of the barrel insulator. b. Remove the spark plug from the engine. In the course of engine operation. carbon and other combustion products Will be deposited on the end of the spark plug and will penetrate the lower threads to some degree ..
\s " result. greater torque is frequently reqUired for removing a plug than for its instillation. Accordingly. the torque limitations given do not apply to plug removal and sufficient torque must be used to unscrew the plug. The higher torque in removal is not as detriment:ll as in installation, since it cannot stretch the threaded section. It docs. however imposc " sheanng load on thiS section and may, if sufficientlv severe. produce a failure in this location. POWER PlANT ISSUED: 8/18/72 2 F2~