PIPER COMANCHE SERVICE MANl:AL 9-5. Checking Generator System, In analyzing complaints of generator-regulator operation. any of several basic conditions may be found. (Refer to figure 9-1.) a. Fully Charged Battery and Low Charging Rate - This indicates normal generator-regulator operation. Regulator setting may be checked as outlined in the following section. b. fully Charged Battery and a High Charging Rate - This indicates that the voltage regulator io; not red ucing the generator output as it should. A high charging rate to a fully charged battery v. ill damage the battery and the accompanying high voltage is very injurious to all electrical units.

This operating condition may result from: I. Improper \ oltage regulator setting. 2. Defective voltage regulator unit. ~. Grounded generator field circuit (in either generator. regulator or wiring). .t. Poor ground connection at regulator. 5. High temperature which reduces the resistance ofthe battery to charge so that it will accept a high charging rate even though the voltage regulator setting is normal. If the trouble is not due to high temperature. determine the cause of trouble by disconnecting the lead from the regulator "f"'terminal v. ith the generator operating at medium speed. If the output remains high.

the generator field is grounded either in the generator or in the wiring harness. If the output drops off. the regulator is at fault. and it should be checked for a high voltage setting or grounds. c. Low Battery and High Charging Rate - This is normal generator-regulator action. Regulator settings may be checked as outlined in the following section. d. Low Battery and Low or ~o Charging Rate - This condition could be due to: I. Loose connections. frayed or damaged wires . .., Defective battery. ~. High circuit resistance. 4. Low regulator setting. S. Oxidized regulator contact points. fl. Defects \\ ithin the generator. If the condition is not caused by loose connections.

frayed or damaged wires. proceed as follows to locale cause of trouble. To determine whether the generator or regulator is at fault. momentarily ground the "F"' terminal of the regulator and increase generator speed. If the output does not increase. the generator is probably at fault and it should be checked as outlined in the Generator Section. If the generator output increases. the trouble is due to: 1. A low voltage (or current) regulator setting. ., Oxidized regulator contact points which insert excessive resistance into the generator field circuit so that output remains low. ~. Generator field circuit open within the regulator at the connections or in the regulator winding. e.

Burned Resistances. Windings or Contacts - These result from open circuit operation or high resistance in the charging circuit. Where burned resistances. windings or contacts are found. always check wiring before installing a new regulator. Otherwise. the new regulator may also fail in the same way. ISSl'ED: 8/18/72 3A14 ELECTRICAL SYSTEM