PIPER COMANCHE SERVICE MANUAL tater, brushes and intemal connections. SUclc.iD1 brah .. , a dirty or cummy commutator (Refer to paralraph 9-18), or poor connections may prevent the poerator from producinl any output. Thrown solder on the cover band indicates that the leaenator h.1 been overloaded (aUowed to produce excessive output) '10 it hu overheated IDd lDelted the solder at the comlillUator riur bars. The solder has b"n thrown out: often, thil leads to an open circuit and bumed cOlDllnltat!3r ban. 1Ј the brushes are satisfactorily se.ted and ant lIlakiallood contact .ith the comlDutator. and the caule of trouble is not apparent. use a let of tnt poiDts aad a tnt l ....
p as foUows to locate the trouble (leads mUlt be dilconnected froID pnerator temina1ll). b. Raile the pounded brush froID the l;:OCDlDut.tor"lIIld insulate .ith piece of cardboard. Check for arounds with test points from the p"erator maill brusb to the lenerator frame. 1Ј the lamp lichts, it indicates that the Ifterator is internally pounded. Location of the IfOllftd can be found by raisiDllDd insulatinl .U brusbes froca the COIIIlDutator and cbecltinl the brush holders, armarote, COlD mutator and field separately. Repair or replace defective part. as required (Refer to paralraph 9-16). MOT! If arounded field is found.
check the replator contact points, since a lI'ounded field may have permitted lift esc"sive field cur- rent which will bave burned the replator coatact points. Bumed regulator poiats sbould be cleaned or replaced u required. e. If the generator is not Founded. check the field for 1ft open circuit with a test lamp. The lamp should Hlht when one test point is placed on the field tenDiDal or arouaded field lead and the other is placed on the brush holder to which the field i. connected. If it does not lilht, the Circuit is open. If the open is due to brokell lead or bad connection. it can be repaired. but if the open is inside one of the field coils. it must be replaced. d.
If the field is not open. check for a short circuit iD the field by connectlna a battery of the speCified voltage and an ammeter in series with the field circuit. Proceed with care, since a shorted field may draw excessive current wltich !Dilht d_ace the lIIIImeter. If the field is not within specification, new field coila will be required (Refer to paraaraph 9-16). MOT! If a shorted field is found, check the reculator contact points, since a shorted field may have penDitted exces.ive field current which would have caused the reauJ.ator contact points to bum. Clean or replace points as required. e. If the trouble has not yet been located. check the armature for open and short circuits.
Open dreuits in the armature are usually obvious, since the open circuited commutator bars will arc every time they pass uftder the leneratcr bru.h so that they will soon become bumed. If the bars are not too badly bumed and the open circuit can be repaired, the armature can usually be saved. In addition to repairine the armature. lenerator output mUlt be brou&ht down to specifi- cations to prevent overlo.dine by readjustment of the replator. Ј. Short circuits in the armature are located by use of a Itowler. The armatute is placed in the irowler and slowly rotated (while a thin Strip of steel such u a hacksaw blade is held above ELECTRICAL SYSTEM ISSUED: 8/18/72 3 A17