BAIC — BAIC Comanche Service Manual: Comprehensive Guide for PA-24 Series Aircraft

PIPER COMANCHE SERVICE MANl'Al f. The drive end head supports a sealed. prelubricated ball bearing in which the drive end of the rotor shaft rotates. 9·6Ic. Checking Alternator System. The ammeter is equipped to check the electrical output-input of the battery. Should the alternator sho .... no output on the ammeter. check the alternator output and field thermo circuit protector s. and ammeter line fuses. If a further check of the ammeter shows no output from the a uernaror. check the a lremator system. (Refer to Figure 9~27b.) a. Ascertain that the ammeter is operating properly. b. Disconnect the battery lead (+) at the alternator. c. Disconnect the field leads (F!

and F2) at the alternator. d. Ascertain that all electrical units are off and the battery is fully charged. e. Turn on the master switch. f. To check the alternator output circuit. connect a voltmeter or 12 volt test light to the battery lead a nd to ground. If a reading of approximately 12 volts registers on the voltmeter or the test light lights. the battery circuit is operational. Should there be no indication of voltage. trace back through the output circuit until voltage is indicated. (Refer to Figure 9·27b.) A component that allows no voltage to pass through it should be replaced. g. To check the field circuit. connect a voltmeter or 12 volt test light to each field lead and to ground.

and separately check as follows: I. A check of the F I circuit will give a variable voltage. if any voltage is indicated on the voltmeter or if any filament glow is indicated on the test light. the circuit is operational. ., The check of the F2 circuit should give a reading of approximately 12 volts or the test lamp should glow normally for an operational circuit. .l. Both the main and auxiliarv field circuits mav be checked in a like manner. 4. I I' indication shows a possible malfunction of the voltage regulator and before installing a new regulator. refer to Paragraph 9-6 Im. For the overvoltage control. refer to Paragraph 9-61 s. h.

If voltage is indicated at both the battery lead and field lead. the alternator should be checked for pos ... ible malfunction. refer to Paragraph 9-61 i. 9~n Id. Adjustments. The only adjustments necessary to maintain the alternator system is the adjustment of the voltage control on the voltage regulator. A voltage of 14.2 volts is maintained. All other control adjust- ments are made at time of installation and need not be reset. IMPORTA~T Since the alternator and regulator are designed for use on only one polarity system. the following precautions must be observed when working on the charging unit.

Failure to observe these precautions will result in serious damage to the electrical equipment. a. When installing a battery. always make absolutely sure the ground polarity of the battery and the ground polarity of the alternator are the same. b. When connecting a booster battery, make certain to connect the negative battery terminals together and the positive battery terminals together. c. When connecting a charger to the battery. connect the charger positive lead to the battery positive terminal and the charger negative lead to the battery negative terminal. d. 'e\er operate the alternator on open circuit. Make absolutely certain all connections in the circuit are secure. )SSt'ED:

8/18/72 3B21 ELECTRICAL S\'STEM