BAIC — BAIC Comanche Service Manual: Comprehensive Guide for PA-24 Series Aircraft

PIPER COMANCHE SERVice MANUAL TA8 LE IX· VII. TROUB LESHOOTING (cont) ELECTRICAL SYSTEM ISSUED: 8/18/72 3 E23 Troubl. Cau.e Rellledy Compound on to" of battery ~elts. Cbar&inl rate too hip. R.duce ebarpDI rate by adjuatinl voltale reaul·tor. Electrolyte runs out of vent plulS. Too much water lidded to battery and ebarlinl rate too bieh. Drain aad keep at proper level and adjust voltage rel'llator. Excessive corrosion inside container. S"m'le from over-fillinl. Vent line. l••kinl or cloned. Ch'rainl rate too bilh. Us. care in addiae water. Re".ir or clean. Adjust voltaee reculator. Sattery freezes. I Diacharpd bettery. Water added and battery not chatpd immedi· ately. Re"lace.

Always recharae battery for 1/2 hout following addition. of water in freezinClII'e.ther. Leaking battery jar. Frozen. Re"lace. Battery j)olanty reversed. Connected beekw.rd. on airplane or charpr. Battery should be slowly dischareed completely and then charged conec:ly .nd t.sted. Battery cansumes excessive water. Charline rate too hip (if in .11 cells). Cracked jar (one cell only). Correct charcinl rate. Replac:e bettery. GENERATOR Generator operating within fate If the voltace is low. tbe lenerator is operating on residual mapetiam. Check for loose or hilh resistance connections: clean and tiahten.