PIPER COMANCHE SERVICE MANUAL TABLE XI·V. ALT1METER INSTRUMENTS REVISED: 4/10/81 3 69 Trouble Clue Remedy Excessive scale error. Improper Qlibrarion adjust- menr, Replace instrUment. Excessive pointer cm:illation. Defective mecbanism. I Replace instrument. High reading. Improptr venting. Eliminate leak in static prt."l$ure system and check aliJnment of airspeed tube. Settl"' knob is hard to rum. Wrona lubrication or lack of lubrication. Replace instrument. Inner reference marker fails to meve when setting knob is rotated. OUt of Cftg2lement. Replace insrrument. i I Settlng knob in Krl:W loose or missing. Excessive vibrauon. I Tightcn mstrument screw. I if lOOK. Replace in- suummt.
if screw is I missing. i I Cracked or loose cover I glass. Excessive vibration. I Replace instrumcnt. I I j Dull or discolored lummous markings. Age. Replace instNment. I Barometric scale and reference markers out of synchronism. Slippage of mating pam. Barometric scale and reference markers OUt of synchronism with pointers. Drift in mechanism. Reset pointers. refer to the latest revision of AC 43. 13-I.