PIPER COMANCHE SERVICE MANUAL TABLE XI-XIV. FUEL QUANTITY INDICATORS Fuel gauge mdicates over Incomplete ground. I fuel transmitter in fuel I cells. Check ground connections at full. IIIlSTRUMENTS ISSUED: 8/18/72 3 818 Trouble eau. Remedy Fuel gauge fails to Indicate. I I I i Broken wiring. Gauge not operatin,. Float partially or completely filled with fuel. Circuit breaker OUt. Defective selcttDr switch. I Fuel gauge indicates full when tanks are not full. Incomplete ground. Check ground connections u I fuel transmitter in wings. I I Fuel gauge falls to I i change indication when I selector handle is moved. I I ! Selector switch slipping on fuel valve shaft. Defective override switch.
i Replace selector switch. i I I I I i Determine which switch is I malfunctioning. replace I switch. Fuel gauge indicates zero. Fuel selector in "OFF" position. Shorted connection at selector switch or other wiring. Sonna!. Check switch and wirtng. Refer to Section IX. Elec- trical System Dla!Tams. I Fuel gauge indicates fuel ; when cell is empty. 1 I ! I I i Fuel cell is .:oUasping due to & suction created b~' a loose filler neck cap. When tank is collapsed fuel sender arm is held in full position. Check fuel cell ilnd deter- mine if it is collapsed. If so. repair as neeessarv. adjust fillet cap to main- tain tight seal or replace "1p.