Komatsu — SUSPENSION

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD SUSPENSION Unit: mm No.

Remedy 18 Replace 19 20 21 Replacing bushing 22 D85EX-15 10-111 Check item Criteria Interference between thrust washer and seal Standard size Tolerance Standard interference Interference limit Shaft Hole 210 + 0.213 + 0.098 – 0.180 – 0.226 0.278– 0.439 – Interference between thrust washer and seal 140 + 0.140 + 0.100 – 0.061 – 0.124 0.161– 0.264 – Interference between pivot shaft and seal stopper ring 157 + 0.083 + 0.043 – 0.050 – 0.090 0.093– 0.173 – Clearance between pivot shaft and bushing Standard size Tolerance Standard clearance Clearance limit Shaft Hole 148 – 0.145 – 0.208 + 0.099 + 0.035 0.180– 0.307 1.0 Clearance between pivot shaft and bushing 155 – 0.145 – 0.208 + 0.132 + 0.059 0.204– 0.340 1.0