STRUCTURE, FUNCTION AND MAINTENANCE STANDARD COOLING FAN PUMP The relationship between the input current to the EPC valve and the output pressure of the EPC valve is as follows. Operation The output pressure of the EPC valve is applied to the piston chamber to push the piston. Piston (6) pushes spool (5) until it is balanced with the spring. Then, the land of the servo piston pressure pas- sage is connected to the pump discharge pas- sages by the cut of spool (5) and the discharge pressure is led to the servo piston. The servo piston is raised by the rocker cam. The position feedback is applied and the lever moves to compress the spring.
If spool (5) is pushed back, the pump discharge circuit and the servo piston circuit are shut off. The pressure in the servo piston chamber lowers and the rocker cam returns toward the maximum swash plate angle. These processes are repeated until the swash plate is fixed to a position where the EPC output is balanced with the spring force. Accordingly, as the EPC output pressure is heightened, the swash plate angle is decreased. As the EPC output pressure is lowered, the swash plate angle is increased. D85EX-15 10-125