Komatsu — COOLING FAN MOTOR

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD COOLING FAN MOTOR 4. Safety valve Function When the engine is started, the pressure in port P of the fan motor is heightened in some cases. Safety valve (1) is installed to protect the fan sys- tem circuit. Operation If the pressure in port P rises above the cracking pressure of safety valve (1), valve (2) of safety valve (1) opens to release the hydraulic oil into port T . By this operation, generation of abnormal pres- sure in port P is prevented. D85EX-15 10-131