Komatsu — ACCUMULATOR

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD ACCUMULATOR ACCUMULATOR For PPC valve 1. Glass plug 2. Shell 3. Poppet 4. Holder 5. Bladder 6. Oil port Specifications Type of gas: Nitrogen Gas volume: 300 cc Max. actuation pressure: 3.1MPa {32kg/cm 2 } Max. actuation pressure: 1.2MPa {12kg/cm 2 } Function The accumulator is installed between the reduc- ing valve and the PPC valve. Even if the engine is stopped with the hydraulic still raised, the pressure of the nitrogen gas compressed inside the accumulator sends the pilot pressure to the main control valve to actuate it and enable the hydraulic to move down under its own weight.

Operation After the engine is stopped, when the PPC valve is at neutral, chamber A inside the bladder is compressed by the oil pressure in chamber B . When the PPC valve is operated, the oil pres- sure in chamber B goes below 2.9 MPa {30 kg/ cm 2 }, and the pressure of the nitrogen gas in chamber A expands the bladder, so the oil in chamber B acts as the pilot pressure and actu- ates the main control valve. 10-134 D85EX-15