Komatsu — PCCS LEVER

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD PCCS LEVER 2. Output voltage characteristics The control unit is installed to the left control stand and the control lever is installed directly onto it. The operating angle (stroke) of the control lever is sensed with potentiometers and signal volt- ages are output to the transmission, steering controller. A potentiometer is installed in each of longitudi- nal direction and lateral direction. Each potenti- ometer outputs 2 signal voltages which are opposite to each other as shown in the figure at right. 10-156 D85EX-15