STRUCTURE, FUNCTION AND MAINTENANCE STANDARD CONTROL VALVE OPERATION OF MAIN CONTROL VALVE 1. AT HOLD (OPERATION OF UNLOAD VALVE) Function When the main spool is at the HOLD position, it drains the excess oil discharged by the pump, and prevents the pressure from being formed in the circuit from rising. When FO becomes larger than set load FS of spring (2), the spool moves to the right and con- nects the passage between chamber A and chamber B , so the oil from the pump is drained. Therefore, spool (1) is balanced at a position that matches the supply of oil from the pump.
Actually, the amount of oil supplied from the pump is small, so the pressure in the circuit is almost the same as the set load of spring (2). Operation When the main spool is at the HOLD position, the pump pressure passes from chamber A through throttle (4) to chamber D . Chambers C and are connected to the drain circuit. When oil is supplied from the pump, the pressure in chamber D rises, and spool (1) is pushed to the right by pressure which is determined by the cross–sectional area of piston (3) receiving the pressure. D85EX-15 10-169