Komatsu — CONTROL VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD CONTROL VALVE Chamber C and chamber D are connected, and the oil from the pump flows through ports A , B , C and D to HSS motor (6). At the same time, the load pressure in chamber D passes through LS ofifice (5) and chamber H , and is sent to chamber G . It is also sent from the LS circuit O to pump servo valve (7). The condition of the pressure of spool (3) is chamber B pressure chamber C pressure, and chamber G pressure chamber D pres- sure, so spool (3) is controlled by the differential pressure of spool (1) (chamber C pressure – chamber D pressure), and balances with spring (4).

In other words, if the oil flow is too large, the dif- ferential pressure of spool (1) becomes larger, so spool (3) moves in the direction to throttle the oil flow; On the other hand, if the oil flow is too small, spool (3) moves in the direction to increase the oil flow. In addition, pump servo valve (7) is controlled so that the differential pressure between pump pressure P and LS pressure LS ( LS differential pressure: PLS ) remains constant, so a suitable amount of oil flows to ensure that the loss of pressure at the control valve ( PLS’ ) is equal to PLS .

The loss of pressure in the control valve is deter- mined by the area of the opening of the main spool, so the oil flow matches the opening of the spool. The return oil flow from the HSS motor (6) passes through chamber E and chamber F , and is drained. D85EX-15 10-173