STRUCTURE, FUNCTION AND MAINTENANCE STANDARD CONTROL VALVE Function If the blade moves down under its own weight, the oil flow of return oil from cylinder is controlled by the area of the opening of main spool (1). Operation When the spool port is opened by pilot pressure PI , because of the weight of the blade, the oil at the cylinder head passes through ports A , B , C and D , and is drained to the tank. When this happens, the flow of return oil from the lift cylinder is throttled by the area of opening between ports A and B , so the downward speed is controlled.
The oil flowing from the cylinder head end passes from the drain circuit through suction valve (2) and is supplied to the bottom end of the cylinder. The oil discharged from the pump passes through ports , , , and , and is sup- plied to the cylinder bottom. D85EX-15 10-177