STRUCTURE, FUNCTION AND MAINTENANCE STANDARD CONTROL VALVE Function When the lift valve is at FLOAT, the cylinder port and drain port are connected to put the circuit in a no–load condition. When the lift valve is in the FLOAT condition, the pump passage and cylinder ports A3 and B3 are separated so that the other control valves can be operated. Operation When the work equipmentc control lever is at the FLOAT position, if pressure PA3 becomes 3.4 MPa (35 kg/cm 2 ) or more, lift spool (1) is moved to the maximum stroke position. In this condition, ports A3 and B3 and the LS passage O are all connected to the drain circuit, so there is no load on the lift cylinder.

If the cylinder is driven by the weight of the blade, the oil entering from port A3 flows to ports A , B , and , while the rest of the oil flows through ports C and D , and is drained. When this happens, the oil flows is throttled by the area of opening between ports A and B of spool (1), and the cylinder speed is controlled. The pump circuit chamber E and ports A3 and B3 are separated, and pump pressure P is formed, so it is possible to carry out compound operations with other control valves. D85EX-15 10-179