STRUCTURE, FUNCTION AND MAINTENANCE STANDARD CONTROL VALVE Function When steering valve (1) and work equipment valve (2) are relieved at the same time, the pump pressure is separated by pressure compensation valve (3) in the work equipment valve, and the port pressure is maintained at a constant value. Operation If HSS motor (6) reaches the stall condition, the load pressure increases and LS relief valve (4) for the steering valve is actuated, so the system is cut off For details, see Item (1) Steering valve ). When this happens, the pump pressure is main- tained at 38.2 MPa (390 kg/cm 2 ), and this is sent to chamber G of the work equipment valve.
When work equipment valve (2) is ooperated and the load on the work equipment valve is greater, work equipment LS relief valve (5) is actuated, and drain oil flow Q1 flows to LS circuit O . As a result, a differential pressure is generated on the left and right sides of pressure compensa- tion valve (4) by LS throttle M of spool (2), and it moves the full stroke to the right. When this happens, the opening between cham- bers D and E is throttled to the minimum size (pump pressure separated). Oil flow Q1 is determined by pump pressure P and the total pressure loss ( P LSO ) of ports C , D , E , F , G , I , J and K .
Furthermore, pressure P2 (the pressure in chamber H ) becomes the total ( LSO + PO ) of the circuit pressure loss of ports H , I , J and K , and the set pressure of work equipment LS relief valve (5). D85EX-15 10-185