STRUCTURE, FUNCTION AND MAINTENANCE STANDARD CONTROL VALVE Function It consists of a parallel circuit, so when com- pound operations are carried out, the oil flow is divided according to the size of each spool open- ing. Operation When tilt spool (1) and lift spool (2) are at the HOLD position or are operated, steering priority valve (3) is pushed completely to the right, and the size of the opening to the downstream area is at its maximum. Tilt spool (1) and lift spool (2) are actuated by PPC valve output pressure PA2 and PB3 , and each is balanced at a position that matches its own pilot pressure. 1.

When pressure P2 P3 Lift valve load pressure P3 is sent to pump LS valve (4) through LS passage O . (1) When pump swash plate does not reach maximum angle When the maximum flow of oil from the pump is greater than the total of the oil flow demanded by the tilt valve and lift valve, an oil flow that matches the opening of the spool flows to both the tilt valve and lift valve. (2) When pump swash plate is at maximum angle When the maximum flow of oil from the pump is smaller than the total of the oil flow demanded by the tilt valve and lift valve, the flow of oil to the tilt valve and lift valve is divided according to differential pressurse PO P2 and differential pressure PO P3 .

In other words, more oil flows to P2 where the load is small. a In cases where the blade is raised in the air and the tilt valve and lift valve (for raise) are operated at the same time, the tilt valve load pressure is smaller than the lift valve load pressure, so the flow of oil to the tilt valve is given priority. In addition, the oil flow demanded by the tilt valve is smaller, so the condition is just as if priority was given to the oil flow for the tilt valve. 2. When pressure P2 = pressure P3 P P2 P P3 , so an oil flow proportional to the size of the spool opening is distributed to each spool. D85EX-15 10-189