TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS 20-8 D85EX-15 (2) Machine model D85EX, PX-15 Category Item Measurement conditions Unit Standard value for new machine Service limit value Work equipment Hydraulic drift Hydrau- lic drift of machine lifted by ripper (for EX) • Hydraulic oil temperature: 45 – 55°C • Engine: Stopped • Measure reduction of sprocket center height h (for 5 minutes). mm Max. 50/5 minutes 100/5 minutes Leakage from cylinder Blade tilt cylinder • Engine: High idling • Hydraulic oil temperature: 45 – 55°C • Relieve cylinder and measure leakage for 1 minute.
cc/min 4 16 Ripper lift cylin- der (for EX) 4 16 Ripper tilt cylin- der (for EX) 4 16 Cooling fan Fan speed • Fan 100% speed mode • Engine: Low idling Min. speed rpm 800 ± 50 400 • Fan 100% speed mode : • Engine High idling Max. speed 1,500 ± 50 1,400 Fan pump pressure • Fan 100% speed mode : • Engine High idling MPa {kg/cm2} 11.8 – 14.7 {120 – 150} 16.17 – 19.11 {165 – 195}