Komatsu — SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS)

TESTING AND ADJUSTING SPECIAL FUNCTIONS OF MONITOR PANEL (EMMS) 5. Maintenance interval change mode (5-EXCHG. INTVAL. SET MODE) In this mode, you can check and set the mainte- nance interval times of various filters and oils which are the bases of the maintenance display function in the operator mode. 1) Selecting and executing mode i) Select “Maintenance interval change mode” on the mode selection screen. a If the mode is selected, code (1C) is displayed on gear speed display sec- tion (1) and the title is displayed on multi-information section (2). ii) Display the maintenance item selection screen by operating buzzer cancel switch (4). [ ]: Execute mode.

2) Selecting and displaying maintenance item i) Operate information switch (5) on the maintenance item selection screen to select a maintenance item. [ > ]: Next code [ ii) Display the maintenance item selection screen by operating buzzer cancel switch (4). [ ]: Execute item. 3) Contents of information section The following items are displayed on the information section. : Code : Maintenance item : Replacement interval time (Set time) a The items shown at right are examples. a If the replacement interval does not need to be changed, finish the operation on this screen. a If the replacement interval needs to be changed, go to step 4). D85EX-15 20-171 (1)