TROUBLESHOOTING ERROR CODE AD10L3 Note 1: Follow the procedure below to check, clean, and replace the filter and strainer. 1) Gauze filter: Disassemble and check. If the filter is clogged, clean it. 2) Gauze filter upstream strainer: If the gauze filter is clogged, also clean the upstream strainer. 3) Fuel filter: If abnormality is not yet recovered after steps 1) and 2), replace the fuel filter. Note 2: When the low-pressure equipment is defective, check the following points:
1) Remaining fuel quantity 2) Feed pump fixing, abrasion, and filter clogging 3) Leak and clogging of low-pressure fuel pipe 4) Defective bypass valve function or other parts assembled erroneously (See the figure below.) 5) Clogged fuel filter 6) Fuel mix in oil pan (Fuel leak in head cover) Fuel low-pressure circuit pressure: 0.15 – 0.3MPa {1.5 – 3.0kg/cm 2 } Figure: Overflow valve (1), bypass valve (2), and fuel inlet joint (3) mounting positions Overflow valve (1): Spring viewed from both holes Bypass valve (2): Spring viewed from nut hole side Fuel inlet joint (3): Gauze filter viewed from both holes D85EX-15 20-421 (1)