TROUBLESHOOTING ERROR CODE D161KB ERROR CODE D161KB (BACK-UP ALARM RELAY: SHORT CIRCUIT (KB)) 20-448 D85EX-15 (1) Action code Error code Controller code Trouble Back-up alarm relay: Short circuit (KB) (Steering and transmission controller system) E01 D161KB Steering and transmission Contents of trouble • Abnormal current flowed in back-up alarm relay circuit at the time of ground output. Action of controller • Stops output to back-up alarm relay circuit. Problem that appears on machine • Back-up alarm is not turned on. Related information • Output state (voltage) to back-up alarm relay can be checked in monitoring mode. (Code 70400:
Back-up alarm relay drive voltage) • Method of reproducing error code: Turn starting switch ON and operate PCCS lever (Reverse position). aThis error code detects abnormality in primary side (coil side) of back-up alarm relay, but not in second- ary side (contact side) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective back-up alarm re- lay (Internal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
BKA (male) Resistance Between (1) – (2) 200 – 400z 2 Hot short circuit in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Short circuit of wiring harness between STC2 (female) (18) – BKA (female) (2) with chassis ground Voltage Max. 1V 3 Defective steering and transmission controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 Parking lever Voltage Between (18) – chassis ground Neutral position 20 – 30V Reverse position Max. 1V