Komatsu — ERROR CODE [D1D0KB] (ENGINE CONTROLLER LOAD POWER SUPPLY RELAY : SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE D1D0KB ERROR CODE D1D0KB (ENGINE CONTROLLER LOAD POWER SUPPLY RELAY: SHORT CIRCUIT (KB)) 20-452 D85EX-15 (1) Action code Error code Controller code Trouble Engine controller load power supply relay: Short circuit (KB) (Engine controller system) CALL 04 D1D0KB ENG Contents of trouble • Voltage is generated in controller load power supply circuit when starting switch is turned OFF. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine, transmission, and brake. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it cannot travel any more.

Related information • Method of reproducing error code: Turn starting switch OFF. aThis error code detects abnormality in secondary side (contact side) of engine controller load power supply relay, but not in primary side (coil side) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine controller load power supply relay (In- ternal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. PPR (male) Resistance Between (3) – (5) Min.

1Mz 2 Hot short circuit in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Short circuit of wiring harness between EGC3 (female) (1), (2), (21) – PPR (female) (3) with chassis ground Voltage Max. 1V 3 Defective engine controller aPrepare with starting switch OFF, then carry out troubleshooting with starting switch OFF or ON. EGC3 Starting switch Voltage Between (1), (2), (21) – chassis ground OFF position Max. 1V ON position Max. 8V