Komatsu — ERROR CODE [DD12KB] (SHIFT UP SWITCH:SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE DD12KB ERROR CODE DD12KB (SHIFT UP SWITCH: SHORT CIRCUIT (KB)) D85EX-15 20-481 (1) Action code Error code Controller code Trouble Shift up switch: Short circuit (KB) (Steering and transmission controller system) E02 DD12KB Steering and transmission Contents of trouble • Signals of two systems of shift up switch circuit were turned ON (CLOSE) at the same time. Action of controller • Flashes caution lamp and turns on caution buzzer. • Recognizes that switch is not pressed. Problem that appears on machine • Shift up is not possible. • Auto shift down does not function.

Related information • Of signals of two systems of switch, NO is for operation detection and NC is for error detection. • Input state (ON/OFF) from shift up switch can be checked in monitoring mode. (Code 40905: Steering and transmission controller input signal 1) • Method of reproducing error code: Turn starting switch ON and operate shift up switch. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective shift up switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

SFTU (male) Shift up switch OFF (Release) ON (Press) Resistance between (2) – (3) Max. 1z Min. 1Mz Resistance between (2) – (1) Min. 1Mz Max. 1z 2 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between STC1 (female) (12) – SFTU (female) (3) with chassis ground Resistance Min. 1Mz Short circuit of wiring harness between STC3 (female) (9) – SFTU (female) (1) with chassis ground Resistance Min.

1Mz 3 Defective steering and transmission controller aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting. STC1, STC3 Shift up switch OFF (Release) ON (Press) Voltage between STC1 (12) – STC1(4) Max. 1V 5 – 11V Voltage between STC3 (9) – STC1(4) 5 – 11V Max. 1V