TROUBLESHOOTING ERROR CODE DD14KB DDQ2KB ERROR CODE DD14KB DDQ2KB (PARKING LEVER SWITCH: SHORT CIRCUIT (KB)) D85EX-15 20-489 (1) Action code Error code Controller code Trouble Parking lever switch: Short circuit (KB) (Steering and transmission controller system) CALL E03 DD14KB DDQ2KB Steering and transmission Contents of trouble • Signals of two systems of parking lever switch circuit were turned ON (CLOSE) at the same time. Action of controller • Flashes caution lamp and turns on caution buzzer. • Recognizes parking lever is in Free position. • Limits operation of engine, transmission, and brake.
Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • Of signals of two systems of switch, NO is for operation detection and NC is for error detection. • Input state (ON/OFF) from parking brake switch can be checked in monitoring mode. (Code 40905: Steering and transmission controller input signal 1) • Method of reproducing error code: Turn starting switch ON and operate parking lever.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Parking lever switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. NSW Parking lever Free position Lock position Between (A) – (B) Max. 1z Min. 1Mz Between (A) – (C) Min. 1Mz Max. 1z 2 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting. Wiring harness between NSW (female) (B) – STC2 (female) (15) with chassis ground Resistance Min.
1Mz Wiring harness between NSW (female) (C) – STC2 (female) (5) with chassis ground Resistance Min. 1Mz 3 Defective steering and transmission controller aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting. STC2 Parking lever Free position Lock position Between (15) – chassis ground Max. 1V 5 – 11V Between (5) – chassis ground 5 – 11V Max. 1V