Komatsu — ERROR CODE [DGE2KX] (ENGINE WATER TEMPERATURE SENSOR (FOR HIGH TEMPERATURE): INPUT SIGNAL IS OUT OF NORMAL RANGE (KX))

TROUBLESHOOTING ERROR CODE DGE2KX ERROR CODE DGE2KX (ENGINE WATER TEMPERATURE SENSOR (FOR HIGH TEMPERATURE): INPUT SIGNAL IS OUT OF NORMAL RANGE (KX)) Circuit diagram related to high engine water temperature sensor 20-494 D85EX-15 (1) Action code Error code C ontroller code Trouble Engine water temperature sensor (for high temperature): Input signal is out of normal range (KX) (Engine controller system) CALL E03 DGE2KX ENG Contents of • trouble High engine water temperature sensor signal is out of normal range. • Action of • controller • Flashes caution lamp and turns on caution buzzer. Fixes water temperature signal output for monitor panel at 90%.

Limits operation of engine and transmission. Problem that • appears on • machine • Monitor panel does not display engine water temperature normally. Once machine is stopped, engine speed is limited to medium (half). Once machine is stopped, travel is limited to F1 and R1. • Related information • Engine water temperature (temperature) can be checked in monitoring mode. (Code 04102: Engine water temperature (High temperature side)) Method of reproducing error code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Defective high engine water temperature sensor (Inter- 1 nal disconnection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. TWH Resistance Between (1) – (2) 3.5k – 90kz Between (1), (2) – chassis ground Min. 1Mz Resistance 3.5k – 90kz Min. 1Mz Disconnection in wiring har- ness (Disconnection in wir- 2 ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC2 (female) (27) – Resistance Max.

1z TWH (female) (1) Wiring harness between EGC2 (female) (39) – Resistance Max. 1z TWH (female) (2) Resistance Max. 1z Resistance Max. 1z Short circuit with chassis 3 ground in wiring harness (Contact with ground circuit aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between EGC2 Min. ) (female) (27) – TWH (female) (1) with chassis Resistance 1Mz ground Resistance Min. 1Mz 4 Defective engine controller aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. EGC2 (female) Resistance Between (27) –(39) 3.5k – 90kz Between (27), (39) – Min.

1Mz chassis ground Resistance 3.5k – 90kz Min. 1Mz