TROUBLESHOOTING ERROR CODE DH30KX ERROR CODE DH30KX (BOOST PRESSURE SENSOR: INPUT IS OUT OF NORMAL RANGE (KX)) 20-500 D85EX-15 (5) Action code Error code Controller code Trouble Boost pressure sensor: Input is out of normal range (KX) (Engine controller system) E02 DH30KX ENG Contents of trouble • Boost pressure sensor signal is out of normal range. Action of controller • Flashes caution lamp and turns on caution buzzer. Problem that appears on machine • Machine is not affected seriously. Related information • Special adapter (799-601-9420) is necessary for troubleshooting for boost pressure sensor. • Boost pressure (pressure) can be checked in monitoring mode. (Code 36500:
Boost pressure) • Method of reproducing error code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective boost pressure sensor (Internal trouble) aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting. PIM Voltage Between (1) – (3) 4.6 – 5.4V Between (2) – (3) 0.3 – 4.7V 2 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC2 (female) (19) – PIM (female) (1) Resistance Max.
1z Wiring harness between EGC2 (female) (20) – PIM (female) (2) Resistance Max. 1z Wiring harness between EGC2 (female) (39) – PIM (female) (3) Resistance Max. 1z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between EGC2 (female) (19) – PIM (female) (1) with chassis ground Resistance Min. 1Mz Short circuit of wiring harness between EGC2 (female) (20) – PIM (female) (2) with chassis ground Resistance Min. 1Mz Short circuit of wiring harness between EGC2 (female) (39) – PIM (female) (3) with chassis ground Resistance Min.
1Mz 4 Defective engine controller aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting. EGC2 Voltage Between (19) – (39) 4.6 – 5.4V Between (20) – (39) 0.3 – 5.7V