Komatsu — ERROR CODE [DH40KX] (COMMON RAIL PRESSURE SENSOR:INPUT IS OUT OF NORMAL RANGE(KX))

TROUBLESHOOTING ERROR CODE DH40KX ERROR CODE DH40KX (COMMON RAIL PRESSURE SENSOR: INPUT IS OUT OF NORMAL RANGE (KX)) 20-502 D85EX-15 (5) Action code Error code Controller code Trouble Common rail pressure sensor: Input is out of normal range (KX) (Engine controller system) CALL E03 DH40KX ENG Contents of trouble • Common rail pressure sensor signal is out of normal range. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.

Related information • Special adapter (799-601-9420) is necessary for troubleshooting for common rail pressure sensor. • Common rail pressure (pressure) can be checked in monitoring mode. (Code 36400: Common rail pressure) • Method of reproducing error code: Turn starting switch ON or start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective common rail pres- sure sensor (Internal trou- ble) aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting.

PFUEL Voltage Between (1) – (3) 4.6 – 5.4V Between (2) – (3) 0.7 – 4.5V 2 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC2 (female) (19) – PFUEL (female) (1) Resistance Max. 1z Wiring harness between EGC2 (female) (40) – PFUEL (female) (2) Resistance Max. 1z Wiring harness between EGC2 (female) (39) – PFUEL (female) (3) Resistance Max.

1z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between EGC2 (female) (19) – PFUEL (female) (1) with chas- sis ground Resistance Min. 1Mz Short circuit of wiring harness between EGC2 (female) (40) – PFUEL (female) (2) with chas- sis ground Resistance Min. 1Mz Short circuit of wiring harness between EGC2 (female) (39) – PFUEL (female) (3) with chas- sis ground Resistance Min. 1Mz 4 Defective engine controller aPrepare with starting switch OFF, turn starting switch ON and carry out troubleshooting.

EGC2 Voltage Between (19) – (39) 4.6 – 5.4V Between (40) – (39) 0.3 – 5.7V