TROUBLESHOOTING ERROR CODE DK10KX ERROR CODE DK10KX (FUEL CONTROL DIAL: INPUT IS OUT OF NORMAL RANGE (KX)) 20-504 D85EX-15 (1) Action code Error code Controller code Trouble Fuel control dial: Input is out of normal range (KX) (Engine controller system) CALL E03 DK10KX ENG Contents of trouble • Signal voltage of fuel control dial circuit is below 0.5V or above 4.5V. Action of controller • Flashes caution lamp and turns on caution buzzer. • Continues controlling with signal of decelerator pedal potentiometer. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half).
• Once machine is stopped, travel is limited to F1 and R1. Related information • Inputting from fuel control dial (Voltage) can be checked in monitoring mode. (Code 03000: Voltage of fuel control dial) • Method of reproducing error code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuel control dial (Internal disconnection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
DIAL (male) Resistance Between (1) – (3) 4.0 – 6.0kz Between (1) – (2) 0.25 – 7.0kz Between (2) – (3) 0.25 – 7.0kz 2 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC2 (female) (9) – DIAL (female) (1) Resistance Max. 1z Wiring harness between EGC2 (female) (10) – DIAL (female) (2) Resistance Max. 1z Wiring harness between EGC2 (female) (29) – DIAL (female) (3) Resistance Max.
1z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between EGC2 (female) (9) – DIAL (female) (1) with chassis ground Resistance Min. 1Mz Resistance Short circuit of wiring harness between EGC2 (female) (10) – DIAL (female) (2) with chassis ground Resistance Min. 1Mz 4 Short circuit with power source in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Short circuit of wiring harness between EGC2 (female) (9) – DIAL (female) (1) with chassis ground Voltage Max. 1V Short circuit of wiring harness between EGC2 (female) (10) – DIAL (female) (2) with chassis ground Voltage Max. 1V 5 Defective engine controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. EGC2 Voltage Between (9) – (29) 4.6 – 5.4V Between (10) – (29) 0.5 – 4.5V