TROUBLESHOOTING ERROR CODE DK12KX ERROR CODE DK12KX (DECELERATION POTENTIOMETER: INPUT IS OUT OF NORMAL RANGE (KX)) 20-506 D85EX-15 (1) Action code Error code Controller code Trouble Fuel control dial: Input is out of normal range (KX) (Engine controller system) CALL E03 DK12KX ENG Contents of trouble • Signal voltage of deceleration potentiometer circuit is below 0.3V or above 4.5V. Action of controller • Flashes caution lamp and turns on caution buzzer. • Continues controlling with signal of fuel control dial. • Limits operation of engine and transmission. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half).
• Once machine is stopped, travel is limited to F1 and R1. Related information • Inputting from deceleration potentiometer (Voltage) can be checked in monitoring mode. (Code 50101: Voltage of deceleration potentiometer) • Method of reproducing error code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective deceleration po- tentiometer (Internal discon- nection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
DCL (male) Resistance Between (A) – (C) 4.0 – 6.0kz Between (A) – (B) 0.25 – 7.0kz Between (B) – (C) 0.25 – 7.0kz 2 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC2 (female) (9) – DCL (female) (A) Resistance Max. 1z Wiring harness between EGC2 (female) (38) – DCL (female) (B) Resistance Max. 1z Wiring harness between EGC2 (female) (29) – DCL (female) (C) Resistance Max.
1z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between EGC2 (female) (9) – DCL (female) (A) with chassis ground Resistance Min. 1Mz Short circuit of wiring harness between EGC2 (female) (36) – DCL (female) (B) with chassis ground Resistance Min. 1Mz 4 Short circuit with power source in wiring harness (Contact with 24V circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Short circuit of wiring harness between EGC2 (female) (9) – DCL (female) (A) with chassis ground Voltage Max. 1V Short circuit of wiring harness between EGC2 (female) (36) – DCL (female) (B) with chassis ground Voltage Max. 1V 4 Defective engine controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. EGC2 Voltage Between (9) – (29) 4.6 – 5.4V Between (38) – (29) 0.3 – 4.5V