Komatsu — ERROR CODE [DLE3LC] (ENGINE NE SPEED SENSOR :SEE TABLE (LC))

TROUBLESHOOTING ERROR CODE DLE3LC ERROR CODE DLE3LC (ENGINE NE SPEED SENSOR: SEE TABLE (LC)) D85EX-15 20-529 (1) Action code Error code Controller code Trouble Engine Ne speed sensor: See table (LC) (Engine controller system) CALL E03 DEL3LC ENG Contents of trouble • Cylinders cannot be identified by signal of engine NE speed sensor. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine and transmission. Problem that appears on machine • Engine speed may become unstable or engine may stop. • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1.

Related information • Special adapter (799-601-9410) is necessary for troubleshooting for engine Ne speed sensor. • Method of reproducing error code: Start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine Ne speed sensor (Internal disconnec- tion or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. NE (male) Resistance Between (1) – (2) 85 – 210z Between (1), (2) – chassis ground Min.

1Mz 2 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between EGC2 (female) (36) – NE (female) (1) Resistance Max. 1z Wiring harness between EGC2 (female) (26) – NE (female) (2) Resistance Max. 1z 3 Short circuit with chassis ground in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between EGC2 (female) (36) – NE (female) (1) with chassis ground Resistance Min.

1Mz Short circuit of wiring harness between EGC2 (female) (26) – NE (female) (2) with chassis ground Resistance Min. 1Mz 4 Defective engine controller aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. EGC2 (female) Resistance Between (36) – (26) 85 – 210z Between (36), (26) – chassis ground Min. 1Mz