Komatsu — E-2 THE PREHEATER DOES NOT OPERATE.(MANUAL PREHEATING FUNCTION)

TROUBLESHOOTING E-2 E-2 THE PREHEATER DOES NOT OPERATE. (MANUAL PREHEATING FUNCTION) D85EX-15 20-605 (1) Trouble • The preheater does not operate. (Manual preheating function) Related information aThis troubleshooting describes the procedures to be followed when the manual preheating function can- not heat the electrical intake air heater mounting section. (When the preheating lamp only does not come on, carry out the troubleshooting of “The preheating lamp does not come on.”) • For preheating, both the “Automatic Preheating Function” and the “Manual Preheating Function” are available. When either function is performed, the preheating lamp comes on.

• If “the monitor panel does not come on” or “the battery relay does not cause operating sound” hen the starting switch is turned ON, the main electric power supply system supposed to be out of order. So, inspect the main electric power supply system. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective starting switch (In- ternal disconnection) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Starting switch Switch position Resistance Between 250 (B) and 280 (C) OFF Min. 1M z HEAT Max.

1 z 2 Defective heater relay (inter- nal defect) aPrepare with the starting switch OFF, then set the starting switch to HEAT and carry out troubleshooting. Heater relay Voltage Electric power supply : between Terminal HT/A (A) and ground 20 – 30V Signal : between Terminal HT/S (C) and ground 20 – 30V When the both voltages of electric power supply and signal are normal and no operating sound is caused, the heater relay is defective. 3 Defective electrical intake air heater (internal defect) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON.

Electrical intake air heater Continuity Between terminals Continue 4 Disconnection in wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Wiring harness between starting switch 255 (R1) and HT/S (C) Resistance Max. 1z Wiring harness between battery relay c terminal and starting motor, or heater relay A terminal Resistance Max. 1z Wiring harness between heater relay HT/B (B) terminal and electrical intake air heater Resistance Max. 1z