TROUBLESHOOTING E-3 E-3 THE MONITOR PANEL DOES NOT COME ON AT ALL WHEN THE STARTING SWITCH IS TURNED ON. Circuit diagram related to ripper pin puller solenoid D85EX-15 20-607 (1) Trouble • The monitor panel does not come on at all when the starting switch is turned ON. Related informati • When the starting switch is turned ON, the gear speed indicator, the multi information section, the gauge on section and the lamp section come on for approximately 2 sec. and go out.
Possible cau and standar value in nor state Cause 1 Defective fuse FS2-(1) Disconnection of wiring har- ness (Disconnection in wir- 2 ing or defective contact in ses connector) d mal Ground fault of wiring har- 3 ness (Contact with ground circuit) 4 Defective monitor panel Standard value in normal state/Remarks on troubleshooting efective fuse FS2-(1) When the fuse FS-2(1) is cut off, the circuit may have possibly been short-circuited with ground. isconnection of wiring har- ess (Disconnection in wir- ng or defective contact in onnector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON.
Wiring harness between S03 (female) (1) (2) and fuse FS-2(1) outlet Resistance Max. 1z Wiring harness between S03 (female) (3) (4) and ground Resistance Max. 1z round fault of wiring har- ess (Contact with ground ircuit) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Contact of wiring harness between S03 (female) (1), (2) – fuse FS2-(1) with ground Resistance Min. 1Mz efective monitor panel aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. S03 Voltage Between (1) (2) and (3) (4) 20 – 30V