TROUBLESHOOTING E-5 E-5 WHEN THE STARTING SWITCH IS TURNED ON, THE RADIATOR WATER LEVEL CAUTION LAMP FLASHES. Circuit diagram related to monitor panel electric power supply D85EX-15 20-609 (1) Trouble • The radiator water level caution lamp flashes. Related information • When any basic check items are detected to be abnormal before the engine starts, they will flash. Possible causes and standard value in normal state Cause Drop of radiator water level 1 (when the system is normal The main radiator water lev 2 el sensor is defective.
(Internal disconnection) Disconnection of wiring har ness (Disconnection in wir- 3 ing or defective contact in connector) 4 Defective monitor panel Standard value in normal state/Remarks on troubleshooting Drop of radiator water level (when the system is normal A drop of radiator water level was detected, inspect the radiator water ) levels. (The lamp flashes when the level is below the specified level.) The main radiator water lev el sensor is defective. (Internal disconnection) aPrepare with the starting switch OFF, then carry out troubleshooting - without turning the starting switch ON. WLD (male) Radiator water level Resistance Normal level Max. 1z Between (1) and (2) Lower level Min.
1Mz Radiator water level Resistance Normal level Max. 1z Lower level Min. 1Mz Disconnection of wiring har ness (Disconnection in wir- ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting - without turning the starting switch ON. Wiring harness between S03 (female) (11) and Resistance Max. 1z WLD (female) (1) Wiring harness between WLD (female) (2) and Resistance Max. 1z ground Resistance Max. 1z Resistance Max. 1z Defective monitor panel aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. S03 Radiator water level Voltage Normal level Max. 1V Between (11) and Min.
approximately ground Lower level 7V Radiator water level Voltage Normal level Max. 1V Lower level Min. approximately 7V