Komatsu — E-16 THE ALARM BUZZER DOES NOT SOUND OR DOES NOT STOP

TROUBLESHOOTING E-16 E-16 THE ALARM BUZZER DOES NOT SOUND OR DOES NOT STOP. Circuit diagram related to alarm buzzer D85EX-15 20-623 (1) Trouble • The alarm buzzer does not sound or does not stop. Related • information c When a short circuit occurs in the alarm buzzer system, the failure code is displayed but no other failure odes are displayed. 1 2 Possible causes 3 and standard value in normal state 4 5 Cause Standard value in normal state/Remarks on troubleshooting Defective circuit breaker Wh fuse FS2-(1) cur en the fuse FS2-(1) is cut off, a ground fault may have possibly oc- red in the circuit.

aP Defective alarm buzzer (In- ternal disconnection or short circuit) repare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. 217 (male) Resistance Between (1) and (2) 200z Between (1), (2) and ground Min. 1Mz aP Disconnection of wiring har- ness (Disconnection in wir- Wi ing or defective contact in 21 connector) Wi FS repare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. ring harness between S03 (female) (18) and 7 (female) (1) Resistance Max. 1z ring harness between 217 (female) (2) and 2 (1) Resistance Max.

1v aP Ground fault of wiring har- ness (Contact with ground Co circuit) 21 repare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. ntact of wiring harness between FS2 (1) – 7 (female) (2) with ground. Resistance Min. 1Mz aP Defective monitor panel (Gauge/lamp module) repare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. S03 Alarm buzzer Voltage Between (18) and ground At stop 20 – 30V At operation (sounding) Max. 3V