Komatsu — LUBRICATION RELIEF VALVE

STRUCTURE, FUNCTION AND MAINTENANCE STANDARD LUBRICATION RELIEF VALVE LUBRICATION RELIEF VALVE 2. Piston 3. Spring 4. Forward clutch housing A: From oil cooler B: Drain C: Drain Outline The oil leaving the torque converter passes through the oil cooler built in the radiator lower tank. It then goes through the lubrication relief valve and lubricates the transmission and PTO. The lubrication relief valve is installed to the right side face of the forward clutch housing. And pre- vents any abnormal pressure in the lubrication oil. At this time, the oil pressure (cracking pressure) is 0.34 MPa {3.5 kg/cm 2 }. The normal oil pressure is 0.08 – 0.20 MPa {0.8 – 2.0 kg/cm 2 } Unit: mm No.

Remedy 1 Replace D85EX-15 10-37 Check item Criteria Lubrication relief valve spring Standard size Repair limit Free length Installed length Installed load Free leng Installed th load 26 23.7 12.0N {1.22kg} 25.2 11.4N {1.16kg}