Komatsu — REMOVAL

DISASSEMBLY AND ASSEMBLY FLOOR FRAME 7. Disconnect accumulator hose (5). 8. Disconnect 6 PPC hoses from the work equip- ment control valve. [*2] Right-hand PPC hoses: (6) : Ripper lift cylinder RAISE hose Coupler (Port PA4), Color band: Black (7) : Blade lift cylinder LOWER hose Coupler (Port PA3), Color band: Black (8) : Blade tilt cylinder LEFT TILT hose Coupler (Port PA2), Color band: Yellow Left-hand PPC hoses: (9) : Ripper lift cylinder LOWER hose Coupler (Port B4), Color band: Not used (10): Blade lift cylinder RAISE hose Coupler (Port B3), Color band: Not used (11): Blade tilt cylinder RIGHT TILT hose Coupler (Port B2), Color band: Green 11.

Disconnect centralized connectors E21 (15) and E22 (16). 12. Remove right cover (17) on the dashboard side. 9. Remove PPC hose clamp (12). 13. Disconnect receiver tank hose (18) and air con- ditioner compressor hose (19). [*3] a Before disconnecting the air conditioner hose, collect the refrigerant (R134a). 14. Disconnect heater hoses (20) and (21). a Close the heater hose valve on the engine side. a Stop the disconnected hoses with wooden plugs, etc. 15. Remove left cover (22) on the dashboard side. 10. Disconnect 2 drain hoses from the drain merge block. (13): Ripper control valve drain hose (14): Blade control valve hose 30-204 D85EX-15 (5)