Caterpillar — MAINTENANCE INTERVAL SCHEDULE (STANDBY GENERATOR SET ENGINES)

100 Maintenance Section Automatic Start/Stop - Inspect 101039675 Automatic Start/Stop - Inspect (Generator Set) SMCS Code: 4462 the generator set, inspect the position of the control Ensure the following conditions: e The control switches are in the correct position for automatic starting. switchgear and the automatic For more information, see the Operation and Maintenance Manual for the generator and the control panel. 101041029 Batteries - Replace Code: battery. Note: Before connecting the cables, ensure that the key start switch is OFF. 8. Connect the cable from the ground NEGATIVE “-” battery terminal. plane to the transfer switches that are associated with the generator are enabled.

SMCS Install the new 7. Connect the cable from the starting motor to the POSITIVE “+” battery terminal. e The starting system is enabled. e The 5. Remove the used battery. 6. The generator set must be ready to operate under a load at any time. After performing maintenance on switches. Note: Always recycle a battery. Never discard a battery. Return used batteries to an appropriate recycling facility. 1401-510 101039758 Battery Charger - Check SMCS Code: 1401-535 Checking Before Start-Up Check the battery charger for proper operation. If the batteries are properly charged, the needle of the ammeter will register near “O” (zero).

The battery charger must not produce excessive current during start-up. Alternatively, the charger must be automatically disconnected for start-up. If the engine has an alternator, the charger must Batteries give off combustible gases which can explode. A spark can cause the combustible gases to ignite. This can result in severe personal injury or death. Ensure proper ventilation for batteries that are in an enclosure. Follow the proper procedures in order to help prevent electrical arcs and/or sparks near batteries. Do not smoke when batteries are serviced. 1. Turn the key start switch to the OFF position. Remove the key and all electrical loads. 2. Turn OFF the battery charger.

Disconnect the charger. 3. The NEGATIVE “-” cable connects the NEGATIVE “-” battery terminal to the ground plane. Disconnect the cable from the NEGATIVE “-” battery terminal. 4. The POSITIVE “+” cable connects the POSITIVE “+” battery terminal to the starting motor. Disconnect the cable from the POSITIVE “+” battery terminal. be automatically disconnected during engine operation. during start-up and Charging the Battery Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets.

Injury to personnel can be the result. Perform the following procedure to charge the battery: 1. Ensure that the charger is turned OFF. 2. Adjust the voltage of the charger in order to match the voltage of the battery.