Caterpillar — MAINTENANCE INTERVAL SCHEDULE (STANDBY GENERATOR SET ENGINES)

102 Maintenance Section Belts - Replace Use a fine grade of sandpaper to clean the terminals and the cable clamps. Clean the items until the surfaces are bright or shiny. DO NOT 2. Loosen the radiator filler cap slowly in order to relieve any pressure. Remove the radiator filler cap. remove material excessively. Excessive removal of material can cause the clamps to not fit properly. Coat the clamps and the terminals with 5N-5561 Silicone Lubricant, petroleum jelly or MPGM grease. 101041135 Belts - Replace SMCS Code: 1357-510 D6 Remove the used fan drive belt and the accessory drive belt. Install new belts. For applications that require multiple drive belts, replace the belts in matched sets.

Used belts are g00326324 lilustration 61 (1) Coolant drain stretched. Replacing only one belt of a matched set will cause the new belt to carry an excessive load. The additional load on the new belt could cause the new belt to break, Check the belt tension according to the information in the Service Manual, “Specifications” module. To adjust the belt tension, see this Operation and Maintenance Manual, “Alternator and Fan Belts - Inspect/Adjust/Replace” topic (Maintenance Section). After new belts are installed, check the belt tension again after 30 minutes of engine operation at rated rpm.

g00582515 IHustration 62 Location of the cooling system drain plugs 101105275 Cooling System Coolant (DEAC) - Change SMCS Code: 1350-044 Clean the cooling system before the recommended maintenance interval if the following conditions exist: (1) Oil cooler (2) Jacket water pump (3) Engine block Note: If the engine has a jacket water heater, drain the coolant from the heater. 3. Open the coolant drain. Remove the cooling system drain plugs. Allow the coolant to drain. NOTICE e The engine overheats frequently. e The coolant is foaming. e Oil or fuel has entered the cooling system and the coolant is contaminated. Drain the Cooling System 1. Stop the engine and allow the engine to cool.

Close the water inlet for the separate circuit aftercooler (if equipped). Ensure that the engine will not start when the cooling system is drained. Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Service Technology Group: